Immersed probe
The stainless probe enters the measured medium while the protective housing keeps the sensing element stable.
NH93420 series / immersion / 4–20 mA
Keep liquid-level signals stable from the probe to the control system. FOTIMA combines the NH93420 product with a pressure sensor supplier capability and a custom steam pressure sensor manufacturer discussion for demanding industrial environments.

Measurement path
The NH93420 is easier to specify when the measurement chain is clear: the probe senses the pressure condition, the electronics process the signal, and the system receives a standard output.
The stainless probe enters the measured medium while the protective housing keeps the sensing element stable.
Liquid pressure is compared with atmospheric pressure through the vented cable path and sensor structure.
High-accuracy circuitry converts the measured level condition into a standard signal for automation and control.
The official product detail keeps the probe, cable and connection relationship visible during installation planning.
Construction and protection
A sealed, submersible instrument still needs a clear application brief. Record the medium, depth, environment and control-system interface together.
| Construction | All-stainless, sealed, solid-state piezoresistive instrument |
|---|---|
| Working method | Two-wire operation |
| Output | Standard 4–20 mA signal |
| Cable | Waterproof cable with internal vent tube |
| Protection | Reverse polarity, overload current limiting, lightning and RF interference protection |
| Use condition | Long-term immersion when the application and installation are suitable |
Application fit
The listed application fields share a need for dependable level information, but each one brings its own medium, access and maintenance constraints.
Review corrosion, deposits, foam and interference conditions when planning the probe and protection boundary.
Connect level measurement with stable control signals and practical access for inspection and maintenance.
Define immersion depth, cable routing and installation access for tanks, wells or supply infrastructure.
Further reading
Frame electrical, foam, deposit and interference conditions before choosing the instrument.
Read the articleConnect stable sensing with the plant’s control and maintenance workflow.
Read the articleUse construction, output and long-term stability as the starting points for comparison.
Read the articleApplication brief
A focused inquiry helps the transmitter match the medium, depth and control environment instead of treating every tank or process as the same.
FAQ
NH93420 is an all-stainless, sealed, submersible solid-state piezoresistive liquid level transmitter for industrial measurement and control.
It measures the difference between liquid static pressure and atmospheric pressure, then converts that difference into a standard electrical output.
The product is described as a two-wire instrument with a standard 4–20 mA output signal.
Its sealed construction, probe and vented cable are designed for long-term immersion when the application and installation are suitable.
Listed applications include petroleum, chemical plants, power plants, municipal water supply and water-temperature exploration.
Share medium, density, range, immersion depth, output, cable length, temperature, installation conditions and control-system requirements.